WARNING: This is a TRAINING RESOURCE only. It does NOT replace real-world safety training, supervision, or compliance with WHS legislation.
High Risk Interactive

Flexible Steel Wire Rope (FSWR)

CPCCLDG3001 · DOGGING

3D Model — Orbit & Inspect

Click & drag to orbit • Scroll to zoom • Right-click to pan

Anatomy of a Wire Rope

⚪

Core

The central support around which strands are laid. Can be Fibre Core (FC) for flexibility or Independent Wire Rope Core (IWRC) for strength and heat resistance.

❖

Strands

Groups of individual wires twisted together in a helical pattern. A 6×19 rope has 6 strands, each containing 19 wires. More wires per strand = more flexible.

—

Individual Wires

High-carbon steel wires that provide the actual tensile strength. Wire diameter determines rope flexibility vs strength.

⟳

Lay Direction

Regular lay: wires and strands twist opposite directions (most common). Lang lay: same direction (more flexible but prone to unlaying).

◯

Thimble

Metal eye fitting inserted into the rope loop to prevent the eye from being crushed under load. ALWAYS required in sling eyes.

▬

Ferrule / Swage

Aluminium or steel sleeve pressed (swaged) onto the rope to form a permanent eye termination. Must be machine-pressed — never hand-crimped.

Common Constructions

TypeUseFlexibility
6 × 19 General purpose lifting Medium
6 × 24 Running ropes, cranes Good
6 × 36 Multi-layer drums, tight bends High
6 × 7 Standing ropes, guys Low (stiff)

Rule of thumb: More wires per strand = more flexible but less abrasion resistant. Fewer wires = stiffer but better wear resistance.

WLL Calculation

Working Load Limit for FSWR slings with IWRC (6×19 construction):

Single Leg Vertical

WLL = D² × 9.6

D = rope diameter in mm • Result in kg

DiameterWLL (Single Vertical)WLL (2-leg 60°)
8 mm614 kg1,064 kg
10 mm960 kg1,663 kg
12 mm1,382 kg2,394 kg
16 mm2,458 kg4,256 kg
20 mm3,840 kg6,651 kg

Temperature Limits

Core TypeMax TempEffect
Fibre Core (FC) 95°C Fibre degrades, loses internal support
IWRC 200°C Steel core maintains strength longer

Critical Warning

  • Never use FSWR that has been exposed to temperatures above its rated limit
  • Heat-affected rope loses strength permanently — it cannot be “cooled down” and reused
  • Discolouration (blue/brown tint) indicates heat damage — remove from service immediately

Inspection & Rejection Criteria

Inspect FSWR slings before every use. Remove from service if ANY of the following are found:

Reject Immediately If

  • Broken wires: 5% of total wires broken in any one rope lay length
  • Corrosion: visible pitting or rust on wires
  • Kinks: any permanent deformation from mishandling
  • Birdcaging: strands forced outward creating a cage shape (from shock load)
  • Crushing: flattened cross-section from being trapped under load
  • Heat damage: discolouration, melted fibres, or loss of lubricant
  • Ferrule damage: cracked, deformed, or slipping ferrules
  • Missing/illegible tag: no identification = no use
  • Core protrusion: core visible between strands
  • Reduction in diameter: >5% from nominal = internal wear

Good Condition Indicators

  • All wires intact, no broken wires visible
  • Rope well-lubricated, no dry or rusty sections
  • Ferrules/swages intact and unmarked
  • Thimbles seated properly in eyes
  • ID tag legible with current test date
  • Uniform diameter throughout length

Slinging Methods & Factors

MethodFactorUse Case
Single vertical1.0Direct vertical lift
Choker hitch0.8Wrapping around load
Basket hitch2.0U-shape under load
2-leg @ 60°1.73Standard bridle
2-leg @ 90°1.41Wider spread
2-leg @ 120°1.0Maximum safe angle

Never Exceed 120° Included Angle

  • At 120° each leg carries the FULL load weight
  • Above 120° sling legs are being pulled apart — catastrophic failure risk
  • Use a spreader bar if the load requires a wider attachment

Storage & Handling

  • Store on racks or hooks — never on the ground where moisture collects
  • Keep away from chemicals, acids, and salt water
  • Do not drag over sharp edges — use edge protectors
  • Do not tie knots in wire rope — permanent damage to wires
  • Coil properly when not in use — do not kink
  • Re-lubricate periodically per manufacturer’s instructions
  • D:d ratio minimum 20:1 (rope diameter to bend radius)
  • Tag and quarantine defective slings immediately — do not place back in service